Abrasive properties
Ajaragar Company has been able to offer its products in line with the national standard in order to improve the quality of its products by utilizing technology and updating its production process.
The results of the experiments are as follows:
Sound and thermal insulation
Eco-friendly for non-use of contaminating materials
Natural and constant color
Adequate water absorption for bonding between bricks and mortar
Generate custom sizes and requirements
Lack of dandruff (due to the use of good soil)
Resistant to frost
Durability and stability:
If the absorption of bricks is more than 30%, the use of this bricks in the facade is due to the presence of water in the brick and the contact of the brick with cold, the water inside the brick is frozen, causing the disintegration and crushing of the brick.
If the water absorption of bricks is less than 8%, bonding and adhesion between the brick and mortar will not be created and we will not have a solid body.
8 <Water absorption <30
Ministry of Roads and City Planning
Joint-Stock Company of Soil Mechanics and Laboratory
Department of Technical and Soil Mechanics Laboratory
Results of water absorption tests
National Iranian Standard No. 7
Project: Arg bricks Test date: 95/05/20
Sample specs | Brick’s initial weight (g) | Brick weight after 5 hours | Brick water absorption percentage |
Boiling (hot) (saturation) | |||
Arg Brick | 742.8 | 872 | 17.6 |
Pressure Resistance:
The minimum compressive strength of a brick should not be less than 80 kg / cm, and the average is less than 100 kg / cm.
Sample specs | Brick Dimensions | Brick area cm | Maximum force | Pushing resistance | ||
Length | Width | Height | kg | kg/cm | ||
Arg Brick | 20.1 | 5.8 | 3.7 | 116.58 | 45750 | 392 |